Peak shaving
Hotels, hospitals, retail centers and mid-size industryThe battery discharges during the most expensive hours while we stage chillers and air handlers so the peak stays down. Demand charges and on-peak consumption drop.
We store and manage your energy. Lithium iron phosphate battery systems with intelligent control: energy can come from the grid, from solar or from any other source, and we decide when to store it and when to use it, so you pay less and never lose power.
Energy storage and management
Every building has a different energy problem. We start from your utility bill and your operation to decide which one applies.
The battery discharges during the most expensive hours while we stage chillers and air handlers so the peak stays down. Demand charges and on-peak consumption drop.
Instant continuity during an outage, with no noise, fumes or fuel. It works alone or alongside your standby generator.
The battery charges from the grid when energy is cheap and delivers it when it is expensive. You do not need to generate to save.
If you already generate or plan to, the battery stores the surplus and manages it together with the grid. The source is optional; the control is the same.
A battery, inverters and whichever source suits the site, in place of gasoline or diesel generators.
We remove the standby generator and install a lithium iron phosphate battery bank that backs up the same loads, with no fuel and no noise. It also works every day to lower your bill.
It takes over in milliseconds. A generator needs several seconds to start and pick up the load.
No diesel to buy, store or guard, and no risk of theft.
No oil, filters, belts or weekly test runs.
A generator only helps during an outage. A battery also shaves peaks and makes use of cheap energy.
No noise or vibration: it can sit next to offices, guest rooms or neighbors.
It burns no fuel: no smoke, particulates or nitrogen oxides where people work and live.
Every liter of diesel left unburned avoids about 2.7 kg of CO₂.
Used oil, filters and coolant are gone.
The diesel tank goes away, and with it the risk of contaminating soil and drains.
It recharges from the grid or from solar panels. With panels, your backup is renewable.
The study confirms the runtime you need before the generator is removed. Where regulations require a standby generator, as in hospitals, the battery works alongside it.
The system learns your building's load profile. It charges when grid energy is cheapest, or from your own generation if you have it, and discharges during the hours of highest demand. The utility sees a lower peak.
Illustrative example. Your curve and savings depend on your tariff and operation.
Equipment is chosen by how much energy you use, not by property type: a high-consumption home may need a cabinet. All units use lithium iron phosphate (LiFePO4) cells, with manufacturer and installation warranties.
Among the most thermally stable lithium chemistries, with a long cycle life. Cobalt-free.
Every battery room and cabinet has its own thermal design. Temperature decides how long a battery lasts.
The system decides when to charge and when to discharge based on your tariff and demand. State of charge, power and alarms on your phone.
We specify equipment certified to UL 9540, UL 1741 and IEC 62619, and install to Mexico's NOM-001-SEDE electrical code.
Our business is storing and managing energy. When on-site generation makes sense, we integrate these technologies into the same system.
They capture light on the front and on the rear, which uses the light reflected off the roof or the ground. Our first in-house system runs on 648 W bifacial modules.
For sites with steady wind: they also generate at night and on cloudy days, when panels do not. We specify them only after measuring the wind on site.
Exterior cladding that looks like stone, wood or brick and generates electricity. It has no glass and sits on an aluminum backing, so a wall that could never take a conventional panel becomes a generator.
About 100 W per m² · roughly 15 kg per m² · panels from 1,140 × 570 × 30 mm · minimum order of 50 m². Manufacturer data, to be confirmed in each quote.
The mobile office at the Children's Hospital job site in Guadalupe, Nuevo León, used to run on a 9 kW gasoline generator. Today it runs on an APEpower battery charged by solar panels.
No sign-up and no commitment. The result is guidance; the formal study is done with your bills.
Next step: send us your last twelve bills so we can prepare a study with real numbers.
Tell us about your property and what you want to solve. We reply with a study proposal.
Message us on WhatsApp56 4002 0133 · contacto@apepower.mx